W52009 for Windows for x64 |
SAS Enterprise Miner 14.1 |
Issue(s) Addressed: | Introduced: |
57007 | The HP Cluster node gives "text expression length ... exceeds maximum length ..." errors when data is on Hadoop |
W52001 |
56536 | ALERT - The HPSVM node scores and score code is incorrect when the Active Set optimization method is used and the target variable order is changed |
W52001 |
57104 | Enabling dynamic logging in SAS® Enterprise Miner without requiring a middle-tier restart |
W52001 |
57219 | The number-of-observations-per-target-level value is blank for validation data in the Interactive Decision Tree window |
W52002 |
57139 | Using PMML score code might generate cascading.pipe.OperatorException and cascading.flow.stream errors |
W52003 |
57293 | SAS® Factory Miner returns "ERROR: value too long for type character varying(1000) ..." when displaying tree graph |
W52003 |
57294 | During execution, the increment setting on the Principal Component template is not passed to the SAS® Factory Miner server |
W52003 |
57328 | When using log, log10, or square root transformations, the Transform Score code might give "Syntax error, expecting one of the following ..." |
W52003 |
57329 | Using trimmed data in SAS® Factory Miner causes missing values in the score code |
W52003 |
57584 | Running the Random Forest template in SAS® Factory Miner returns a "Could not open the code file ..." error |
W52003 |
58088 | Score.xml and Score_62.xml files contain none of the output variables from the Score Code Export node, "No outputs detected ..." is displayed |
W52004 |
59355 | The Score Code Export node completes, but the output score XML files might be incorrect when an HP Data Partition node is included |
W52005 |
59398 | ALERT - The StatExplore node standard deviation, skewness, and kurtosis values might be incorrect |
W52005 |
59447 | A pruned Decision Tree might produce incorrect Variable Importance values in the Output panel of the Results window |
W52005 |
59687 | The HP Principal Components node gives incorrect scores and score code when the Eigenvalue Source property is set to Covariance |
W52005 |
60011 | The HP Regression node models an ordinal target as a nominal target |
W52006 |
60050 | HP Transform node Pseudo-Quantile score code might generate missing values |
W52006 |
60054 | Model Comparison node does not assess results from an HP SVM node in MPP mode, a "does not exist ..." error might be displayed in the log |
W52006 |
60326 | SAS® Enterprise Miner fails to launch (via Java Web Start) and an "Unable to launch the application" Application Error dialog box is displayed |
W52007 |
61500 | Interactive Grouping node 'No matching IF-THEN clause' error when using Import Grouping data and Special Codes |
W52008 |
61276 | Score node optimized score-code might be incorrect for flows that contain an Interactive Binning node |
W52008 |
61495 | HP SVM node scored-results do not include an ID (KEY) variable |
W52008 |
61502 | Output rules from the Sequence Node in SAS® Enterprise Miner(tm) are limited to 200 characters |
W52008 |
61523 | Model-fit statistics seem to be incorrect when an HP Data Partition node is used |
W52008 |
NOTE: If you install this hot fix and have SAS Text Miner 14.1 installed, you must also install hot fix W69004 for SAS Text Miner 14.1.
If you install this hot fix and have SAS Factory Miner 14.1 installed, you must also install hot fix W95001 for SAS Factory Miner 14.1.
If you install this hot fix and have SAS Data Mining Scoring 9.4M3 installed on your system, you must also apply hot fix Z98001 to fully implement the fix for the issue described in 57139. |
|